Results 1 - 20 de 81
Filter
1.
Chinese Journal of Digestion ; (12): 764-769, 2022.
Article in Chinese | WPRIM | ID: wpr-958357

ABSTRACT

Objective:To explore the value of detachable string-magnetically controlled capsule endoscopy (DS-MCE) in the evaluation of post-endoscopic treatment of liver cirrhosis patients with gastroesophageal varices during follow-up, and conventional electronic esophagogastroduodenoscopy (EGD) was used as the gold standard.Methods:From July 1, 2019 to December 31, 2021, 50 follow-up patients with gastroesophageal varices due to liver cirrhosis and had a past medical history of endoscopic treatment in Ruijin Hospital, Shanghai Jiaotong University School of Medicine were selected. DS-MCE and EGD were performed in turn. The 2 endoscopic examination methods were compared and analyzed in the assessment of detecting gastroesophageal varices, grading of diameter of esophageal varices and classification of bleeding risk factors (including sensitivity, specificity, positive predictive value and negative predictive value), diagnosis of portal hypertensive gastropathy and its severity, and the patients′ satisfaction (pre-procedural perceptual and post-procedural satisfaction). Kruskal-Wallis test and Kappa test were used for statistical analysis.Results:The sensitivity, specificity, positive predictive value and negative predictive value of DS-MCE in the diagnosis of esophageal varices were 100.0% (43/43), 85.7%(6/7), 97.7% (43/44) and 100.0%(6/6), respectively.The accuracy of DS-MCE in evaluating the grading of esophageal varices was 86.0% (43/50), with good consistency of EGD, and the Kappa value was 0.797 ( P<0.001). The sensitivity, specificity, positive predictive value and negative predictive value of DS-MCE in the diagnosis of esophageal varices with bleeding risk factors were 94.4% (34/36), 100.0%(14/14), 100.0% (34/34) and 87.5%(14/16), respectively. The accuracy of DS-MCE in evaluating esophageal varices with bleeding risk factors was 94.0% (47/50), with good consistency of EGD, and the Kappa value was 0.862 ( P<0.001). The sensitivity, specificity, positive predictive value and negative predictive value of DS-MCE in the diagnosis of gastric varices were 85.7% (18/21), 93.1% (27/29), 90.0% (18/20) and 90.0% (27/30), respectively. The sensitivity, specificity, positive predictive value and negative predictive value of DS-MCE in the diagnosis of portal hypertensive gastropathy were all 100.0% (50/50). The consistency of DS-MCE and EGD in the severity grading of portal hypertensive gastropathy was good, the Kappa value was 0.962 ( P<0.001). The results of pre-procedural perceptual analysis showed that patients′ psychological tension before examination and expected pain before examination of DS-MCE were better than those of EGD ( H=16.04 and 23.74, both P<0.001). The results of satisfactory analysis after examination indicated that DS-MCE was better than EGD in the degree of difficulty in swallowing, pain and discomfort during examination, pain and discomfort after examination, comfort degree during examination, convenience of the procedure and willingness of receiving such examination again as gastric examination method ( H=17.28, 30.88, 44.68, 34.66, 48.05, 22.74, 13.03 and 17.19, all P<0.001). Conclusions:With EGD as the gold standard, DS-MCE can accurately evaluate gastroesophageal varices and portal hypertensive gastroenteropathy after endoscopic treatment in patients with liver cirrhosis and gastroesophageal varices, and it is a safe and comfortable method. DS-MCE can be an efficient alternative method in endoscopic follow-up of such patients.

2.
Chinese Journal of Digestive Endoscopy ; (12): 471-474, 2021.
Article in Chinese | WPRIM | ID: wpr-912138

ABSTRACT

Objective:To evaluate the safety and efficacy of a novel endoscopic anastomosis clip for the stomach perforation via an animal trial.Methods:Six pigs were used as experimental animals, and two perforation models (10-20 mm in diameter) were created by an endoscopic needle-knife in the stomach of each pig. The perforations were then closed by the novel detachable endoscopic anastomosis clip. The animal survival and healing of the lesions were recorded. All the clips were taken out 30 days after operation through endoscopy. Half of the animals were immediately after clip extraction and the other half of the animals survived for another 30 days owing to observation.Results:All clips were implanted successfully and all lesions healed during 30 days after the operation. All animals survived. The clip natural shedding rate was 33.3%(4/12), and the rest of clips were successfully disassembled and removed. All animals were alive 30 days after clip removal with lesions healed.Conclusion:The novel anastomosis clip is safe and effective in animal experiments with easy to operate. It could be recommended for further clinical research with good clinical prospect.

3.
Chinese Medical Equipment Journal ; (6): 114-116, 2017.
Article in Chinese | WPRIM | ID: wpr-658517

ABSTRACT

Objective To develop a detachable upper limb operation table for facilitating field surgery and improve the utilization rate of surgical shelter in field hospital.Methods The operating table was composed of a rectangular frame made of stainless steel and a table top of insulation board.The width of the rectangular frame was quartered,and two elastic fasteners were placed respectively at the points of a quarter and 3 quarters.The operating table came into being after the two fasteners were connected.Results The table had its height regulated as required and facilitated intraoperative X-ray exposure,and enhanced the efficiency and satisfaction of the surgeon and nurse.Conclusion The table gains advantages in size,carrying,operation and structure,and thus is applicable for upper limb operation in field shelter.

4.
The Journal of Korean Academy of Prosthodontics ; : 180-186, 2017.
Article in Korean | WPRIM | ID: wpr-23892

ABSTRACT

Implant supported prostheses have improved the quality of lives of totally edentulous patients. However, there are some limitations on the number of implants related to the residual bone level or the economic concern and so on. In this situation, applying fixed detachable prosthesis with bilateral cantilevers can be considered. This clinical report describes implant supported prosthetic rehabilitation of a patient with severe bone resorption. The patient was satisfied and felt comfortable with upper complete denture and lower fixed detachable prosthesis.


Subject(s)
Humans , Bone Resorption , Denture, Complete , Mandible , Prostheses and Implants , Rehabilitation
5.
Chinese Medical Equipment Journal ; (6): 114-116, 2017.
Article in Chinese | WPRIM | ID: wpr-661436

ABSTRACT

Objective To develop a detachable upper limb operation table for facilitating field surgery and improve the utilization rate of surgical shelter in field hospital.Methods The operating table was composed of a rectangular frame made of stainless steel and a table top of insulation board.The width of the rectangular frame was quartered,and two elastic fasteners were placed respectively at the points of a quarter and 3 quarters.The operating table came into being after the two fasteners were connected.Results The table had its height regulated as required and facilitated intraoperative X-ray exposure,and enhanced the efficiency and satisfaction of the surgeon and nurse.Conclusion The table gains advantages in size,carrying,operation and structure,and thus is applicable for upper limb operation in field shelter.

6.
Journal of Interventional Radiology ; (12): 754-758, 2015.
Article in Chinese | WPRIM | ID: wpr-481230

ABSTRACT

Objective To evaluate the clinical efficacy of endovascular embolization with detachable balloon, based on the characteristics of traumatic carotid-cavernous fistulae (TCCF), in treating TCCF. Methods The clinical data of 188 patients with TCCF, who had received endovascular embolization with detachable balloon via femoral artery access, were retrospectively analyzed. The risk factors for recurrence were statistically analyzed. Results Of the total 188 patients, complete cure after the first balloon embolization was obtained in 160, certain improvement of clinical symptoms was achieved in 22, and balloon embolization failed in 6, for whom other surgical options had to be carried out. Complications occurred in three patients. Recurrence was seen in 23 patients within the period from one day to 5 years after the treatment, and the recurrent lesion was successfully cured in all patients. Univariate analysis and chi square test or correction chi square test indicated that factors affecting postoperative recurrence were the use of multiple balloons for embolization and the presence of residual fistula after operation (P0.05). Multivariate logistic regression analysis revealed that the independent factors affecting recurrence included the number of used balloon≥2 (OR=7.80, 95%CI:2.28-26.73,P=0.001) and postoperative residual fistula that was observed immediately after the embolization (OR=10.46, 95%CI:2.99-36.50,P=0.000). Conclusion For the treatment of TCCF, transcatheter embolization with detachable balloon is minimally-invasive, safe and reliable with fewer complications, therefore, this technique should be regarded as the therapy of first choice. The use of multiple balloons and the presence of residual fistula observed immediately after the embolization procedure are the risk factors for recurrence. Other possible risk factors are still to be furtherstudied.

7.
Journal of Interventional Radiology ; (12): 373-377, 2015.
Article in Chinese | WPRIM | ID: wpr-464433

ABSTRACT

Objective To summarize the experience in treating coronary artery fistula (CAF) by using Guglielmi detachable coils. Methods During the period from July 2009 to November 2014 at the Affiliated Changhai Hospital of Second Military Medical University, interventional treatment of CAF by using Guglielmi detachable coils was performed in 40 patients. The clinical data were retrospectively analyzed. The feasibility, safety and effectiveness of this technique were evaluated. Results Successful transcatheter closure of CAF with Guglielmi detachable coils was achieved in all 40 patients; the average Guglielmi detachable coils used in each patient was(2.33±1.38) coils. No procedure-related complications occurred. Intra-operative angiography showed that residual shunt completely disappeared in 12 patients (30%) and blood flow was significantly decreased in 28 patients (70%). All the patients were followed up for 1-65 months, neither complications such as recurrent bleeding and ischemia nor stenosis and occlusion of related arteries, or fistula cavity rupture occurred. Conclusion The use of Guglielmi detachable coil in interventional treatment of CAF is safe and effective, although its long-term effect needs to be further verified.

8.
Korean Journal of Radiology ; : 613-621, 2014.
Article in English | WPRIM | ID: wpr-95303

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the effectiveness of detachable interlock microcoils for an embolization of the internal iliac artery during an endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: A retrospective review was conducted on 40 patients with aortic aneurysms, who had undergone an EVAR between January 2010 and March 2012. Among them, 16 patients were referred for embolization of the internal iliac artery for the prevention of type II endoleaks. Among 16 patients, 13 patients underwent embolization using detachable interlock microcoils during an EVAR. Computed tomographic angiographies and clinical examinations were performed during the follow-up period. Technical success, clinical outcome, and complications were reviewed. RESULTS: Internal iliac artery embolizations using detachable interlock microcoils were technically successful in all 13 patients, with no occurrence of procedure-related complications. Follow-up imaging was accomplished in the 13 cases. In all cases, type II endoleak was not observed with computed tomographic angiography during the median follow-up of 3 months (range, 1-27 months) and the median clinical follow-up of 12 months (range, 1-27 months). Two of 13 (15%) patients had symptoms of buttock pain, and one patient died due to underlying stomach cancer. No significant clinical symptoms such as bowel ischemia were observed. CONCLUSION: Internal iliac artery embolization during an EVAR using detachable interlock microcoils to prevent type II endoleaks appears safe and effective, although this should be further proven in a larger population.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Blood Vessel Prosthesis Implantation , Embolization, Therapeutic , Follow-Up Studies , Iliac Artery/surgery , Retrospective Studies , Tomography, X-Ray Computed
9.
Journal of Clinical Neurology ; : 83-90, 2013.
Article in English | WPRIM | ID: wpr-205179

ABSTRACT

BACKGROUND AND PURPOSE: This study evaluated the clinical value of detachable-balloon embolization for traumatic carotid-cavernous fistula (TCCF), focusing on the frequency, risk factors, and retreatment of recurrence. METHODS: Fifty-eight patients with TCCF underwent transarterial detachable-balloon embolization between October 2004 and March 2011. The clinical follow-up was performed every 3 months until up to 3 years postprocedure. Each patient was placed in either the recurrence group or the nonrecurrence group according to whether a recurrence developed after the first procedure. The relevant factors including gender, fistula location, interval between trauma and the interventional procedure, blood flow in the carotid-cavernous fistula, number of balloons, and whether the internal carotid artery (ICA) was sacrificed were evaluated. RESULTS: All 58 TCCFs were successfully treated with transarterial balloon embolization, including 7 patients with ICA sacrifice. Recurrent fistulas occurred in seven patients during the follow-up period. Univariate analysis indicated that the interval between trauma and the interventional procedure (p=0.006) might be the main factor related to the recurrence of TCCF. The second treatments involved ICA sacrifice in two patients, fistula embolization with balloons in four patients, and placement of a covered stent in one patient. CONCLUSIONS: Detachable balloons can still serve as the first-line treatment for TCCFs and recurrent TCCFs despite having a nonnegligible recurrence rate. Shortening the interval between trauma and the interventional procedure may reduce the risk of recurrence.


Subject(s)
Humans , Balloon Occlusion , Carotid Artery, Internal , Fistula , Follow-Up Studies , Recurrence , Retreatment , Risk Factors , Stents
10.
Annals of Coloproctology ; : 31-33, 2013.
Article in English | WPRIM | ID: wpr-120585

ABSTRACT

Vascular ectasia is a well-known cause of lower gastrointestinal bleeding in the elderly. Endoscopically, it usually appears as a flat or elevated bright red lesion. We report on an extremely rare case of a large, pedunculated, polypoid vascular ectasia in an asymptomatic patient. A large pedunculated polypoid mass in the sigmoid colon was observed on colonoscopy during a regular health check-up, and a polypectomy was performed using a detachable snare. In histology, vessels with massive dilation were found mainly in the submucosa, which was consistent with vascular ectasia.


Subject(s)
Aged , Humans , Colon, Sigmoid , Colonoscopy , Dilatation, Pathologic , Hemorrhage , SNARE Proteins
11.
Journal of Korean Neurosurgical Society ; : 19-24, 2013.
Article in English | WPRIM | ID: wpr-63156

ABSTRACT

OBJECTIVE: The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. METHODS: From 2010 to 2011, consecutive 222 patients with an intracranial aneurysm underwent coil embolization. Inclusion criterias were : 1) unruptured intracranial aneurysm, 2) one or more GDC or Target coils used with or without other coils, 3) DWI examination within 24 hours after coiling, and 4) coiling performed without a balloon or stent. RESULTS: Ninety patients (92 cases) met the inclusion criteria. DWI lesions were detected in 55 (61.1%) of 90 patients. In the GDC group (n=44), DWI lesions were detected in 31 (70.5%). The average number of DWI lesions was 5.0+/-8.7 (mean+/-SD; range, 1-40) in aneurysm-related territory. In the Target coil group (n=48), DWI lesions were detected in 24 (50.0%). The number of DWI lesion was 2.1+/-5.4 (range, 1-32) in aneurysm-related territory. There was no significant correlation between a number of coils and DWI lesions. No significant differences were also observed in the number of DWI lesions in each group. CONCLUSION: The GDC and Target coils, which have an electrolytic detachable system, showed no differences in the incidence of DWI lesion.


Subject(s)
Humans , Incidence , Intracranial Aneurysm , Magnetic Resonance Imaging , Retrospective Studies , Thromboembolism
12.
The Korean Journal of Gastroenterology ; : 215-218, 2013.
Article in English | WPRIM | ID: wpr-80217

ABSTRACT

A sharp, impacted fish bone in the esophagus is an indication for urgent endoscopy. Endoscopic removal of such an object is a challenging task. An endoscopic protector hood is then used to remove the object. However, an endoscopic hood protector is not always available. In a patient with a large hiatal hernia, the protector hood may not return to the original shape when it passes through the gastroesophageal junction and therefore may not properly protect the esophageal mucosa from the sharp foreign body. In our case, it was impossible to deploy the endoscopic hood protector through the gastroesophageal junction despite multiple attempts. We propose an alternative solution for such cases. We safely removed a large sharp-edged flat fish bone that was folded and compressed using a detachable snare after releasing and pushing the fish bone into the stomach using an endoscope equipped with a transparent cap used for dilating the esophageal wall. This method of using an endoscopic cap and detachable snare is a safe, useful alternative for endoscopically removing a large sharp-edged flat foreign body from the upper gastrointestinal tract. This alternative technique has not been reported in the English medical literature.


Subject(s)
Aged, 80 and over , Humans , Male , Esophagoscopy/instrumentation , Esophagus , Foreign Bodies/diagnostic imaging
13.
Korean Journal of Radiology ; : 412-416, 2012.
Article in English | WPRIM | ID: wpr-72934

ABSTRACT

OBJECTIVE: Device- or technique-related air embolism is a drawback of various neuro-endovascular procedures. Detachable aneurysm embolization coils can be sources of such air bubbles. We therefore assessed the formation of air bubbles during in vitro delivery of various detachable coils. MATERIALS AND METHODS: A closed circuit simulating a typical endovascular coiling procedure was primed with saline solution degassed by a sonification device. Thirty commercially available detachable coils (7 Axium, 4 GDCs, 5 MicroPlex, 7 Target, and 7 Trufill coils) were tested by using the standard coil flushing and delivery techniques suggested by each manufacturer. The emergence of any air bubbles was monitored with a digital microscope and the images were captured to measure total volumes of air bubbles during coil insertion and detachment and after coil pusher removal. RESULTS: Air bubbles were seen during insertion or removal of 23 of 30 coils (76.7%), with volumes ranging from 0 to 23.42 mm3 (median: 0.16 mm3). Air bubbles were observed most frequently after removal of the coil pusher. Significantly larger amounts of air bubbles were observed in Target coils. CONCLUSION: Variable volumes of air bubbles are observed while delivering detachable embolization coils, particularly after removal of the coil pusher and especially with Target coils.


Subject(s)
Embolism, Air/etiology , Embolization, Therapeutic/adverse effects , Intracranial Embolism/etiology , Magnetic Resonance Imaging/methods , Microscopy , Risk Assessment , Statistics, Nonparametric
14.
Korean Journal of Radiology ; : 111-114, 2012.
Article in English | WPRIM | ID: wpr-23440

ABSTRACT

Pulmonary arteriovenous malformations (PAVMs) are often treated by pushable fibered or non-fibered microcoils, using an anchor or scaffold technique or with an Amplatzer plug through a guiding sheath. When performing percutaneous transcatheter microcoil embolization, there is a risk of coil migration, particularly with high-flow type PAVMs. The authors report on a unique treatment in a patient with a giant high-flow PAVM whose nidus had a maximum diameter of 6 cm. A detachable coil, not detached from a delivery wire (an anchored detachable coil), was first placed in the feeding artery under flow control by balloon occlusion, and then multiple microcoils were packed proximally to the anchored detachable coil. After confirming the stability of the microcoils during a gradual deflation of the balloon, we finally released the first detachable coil. The nidus was reduced in size to 15 mm at one year postoperatively.


Subject(s)
Humans , Male , Middle Aged , Arteriovenous Malformations/therapy , Balloon Occlusion/methods , Catheterization , Contrast Media , Embolization, Therapeutic/instrumentation , Magnetic Resonance Imaging , Pulmonary Artery/abnormalities , Pulmonary Veins/abnormalities , Tomography, X-Ray Computed
15.
Journal of Geriatric Cardiology ; (12): 11-16, 2012.
Article in Chinese | WPRIM | ID: wpr-672085

ABSTRACT

Background Coronary artery fistula (CAF) is a rare anomaly.Transcatheter CAF closure has been introduced using various materials,but only few data are available on the Guglielmi detachable coil (GDC).The advantage of using GDC for transcatheter CAF closure is more controllable,therefore much safer when compared to other coils.This report is about our experience in transcatheter closure of CAF using fibered GDC in our hospital.Methods & Results From 2002 to 2007,there were 10 patients with CAFs (age range:28 to 56 year-old,7 males) who underwent transcatheter CAF closure.There were a total of 19 CAFs which originated from right coronary (n =5),left circumflex (n =3),left anterior descending artery (n =10) and left main trunk (n =1).Median number of coil deployment for each fistula was 3 (range:1 to 6).The pulmonary artery was the most common site of the distal communication of CAFs (n =14),followed by right atrium (n =3),left atrium (n =1) and left ventricle (n =1).Immediate coronary angiography after GDC deployment revealed no residual shunt in 12 (63.2%) CAFs,significant reduction of the flow in 5 (26.3%),while 2 (10.5%) could not be closed due to small size.Nine (90%) patients underwent a repeated angiography within 3 to 8 months.Among 12 CAFs that were occluded immediately post-deployment,there were 2 CAFs with insignificant residual flow.Among 6 CAFs with significantly decreased flow immediately post-deployment,2 were occluded totally in the follow-up angiography.In total,12 (70.5%) CAFs were occluded completely and 5 (29.5%) CAFs still had insignificant residual flow,which did not need any additional coil deployment.During a mean follow up of 4.3 ± 0.7 year,all patients remained symptom and complication free.Conclusions The fibered GDC is a safe and effective method for percutaneous closure of the CAFs.

16.
Chinese Journal of Trauma ; (12): 328-331, 2012.
Article in Chinese | WPRIM | ID: wpr-418643

ABSTRACT

Objective To investigate the main technical points of detachable balloon in management of traumatic carotid-cavernous fistulas (TCCF) and evaluate objectively the clinical outcome.Methods A total of 59 patients with TCCF were treated with detachable balloons,which involved 64 embolization procedures.Follow-up ranged from 3 months to 2 years. Results Forty-eight patients with TCCF (81%) were successfully occluded with patency of internal carotid artery.The rest 11 patients were obstructed in both the fistula and the internal carotid artery.Recurrent TCCF was found within three days after embolization in five patients (with a recurrence rate of 8% ) who underwent further embolization,of whom one patient went blind after the procedtre and the eyesight showed no recovery even after another embolization with balloon for successful occlusion of the fistula; one patient presented with intracerebral hematoma at day 3 postoperatively and underwent emergency embolization again to occlude the internal carotid artery and fistula,with slight paralysis of the left limb. Conclusions Embolization of TCCF with detachable balloon is a reliable treatment,which is characterized by slight injury and high safety.However,the disease' s development should be strictly observed after the treatment.In the case of recurrence of symptoms,brain angiography and CT scanning should be rechecked timely and emergency treatment should be performed.

17.
Chinese Journal of Postgraduates of Medicine ; (36): 29-31, 2011.
Article in Chinese | WPRIM | ID: wpr-413130

ABSTRACT

Objective To investigate the risk factors and treatment experience of cerebral aneurysms rupture in the course of Gugliemi detachable coil (GDC) embolization. Methods From August 2000 to June 2010,420 patients with aneurysmal subarachnoid hemorrhage (SAH) received GDC embolization and their clinical data were retrospectively reviewed to analyse the risk factors of cerebral aneurysms rupture in the course of treatment. Results Sixteen patients had intraoperative aneurysm rupture, the incidence rate was 3.8%(16/420),including 13 cases density filling,3 cases partial filling postoperative.Univariate analysis showed:SAH episodes ≥2 times,tumor size ≤4 mm,the presence of pseudoaneurysm,Hunt-Hess grade Ⅳ - Ⅴ as well as history of hypertension were the risk factors of cerebral aneurysms rupture in the course of GDC embolization. Logistic regression analysis showed:SAH episodes ≥2 times (P = 0.0424,OR =6.798)and the presence of pseudoaneurysm (P = 0.0069, OR = 4.423) were the independent risk factors of cerebral aneurysms rupture. Conclusions Rupture of intracranial aneurysm in the course of GDC embolization is mainly related to the multiple SAH and the presence of pseudoaneurysm. It should be alert to the risk factors and take active treatment as soon as the occurrence of rupture in clinic work, for this, most patients can get a good prognosis.

18.
The Journal of Advanced Prosthodontics ; : 154-159, 2010.
Article in English | WPRIM | ID: wpr-68094

ABSTRACT

BACKGROUND: Generalized aggressive periodontitis (GAP) is a destructive periodontal disease that can develop in young age. Only a few cases of full mouth rehabilitation, using dental implants, have been reported in a patient with aggressive periodontitis. CASE DESCRIPTION: This clinical report describes the treatment procedures and results of full mouth rehabilitation in a patient with aggressive periodontitis. After all teeth were extracted, 6 implants were placed in the maxilla and mandible, respectively. Fixed detachable implant prostheses were made. The patient was satisfied with the final results. She was followed for 10 months postloading. CLINICAL IMPLICATION: For a long-term success, continuous maintenance care is critical, as the contributing factors of the disease (such as immune factors or periodontal pathogens) may not be controlled adequately.


Subject(s)
Humans , Aggressive Periodontitis , Dental Implants , Immunologic Factors , Mandible , Maxilla , Mouth , Mouth Rehabilitation , Periodontal Diseases , Prostheses and Implants , Tooth
19.
Korean Journal of Ophthalmology ; : 322-324, 2010.
Article in English | WPRIM | ID: wpr-62449

ABSTRACT

A 62-year-old woman has been suffered from cavernous sinus thrombophlebitis which was confirmed by four-vessel angiography, orbit magnetic resonance imaging, and blood culture. Three weeks after recovery of cavernous sinus thrombophlebitis, right eye proptosis and complete third, fourth, and sixth cranial nerve palsies developed. Best-corrected visual acuity decreased to 20/70 in the right eye. Repeat magnetic resonance imaging demonstrated a 1.5-cm-sized mass in the right cavernous sinus, suspicious for mycotic aneurysm. Amphotericin B supplementation was begun and was followed by successful transarterial Guglielmi detachable coil embolization. Four months later, extraocular movement was normalized, and visual acuity improved to 20/25 in the right eye.


Subject(s)
Female , Humans , Middle Aged , Amphotericin B/therapeutic use , Aneurysm, Infected/etiology , Angiography , Antifungal Agents/therapeutic use , Cavernous Sinus Thrombosis/complications , Embolization, Therapeutic/methods , Magnetic Resonance Imaging , Visual Acuity
20.
Journal of Interventional Radiology ; (12): 281-286, 2010.
Article in Chinese | WPRIM | ID: wpr-402650

ABSTRACT

Objective To present our single-center experience in treating traumatic direct carotidcavemous fistulas (TDCCFs)by using detachable balloon,coil and Willis covered stent via arterial route.Methods During the last five years,transarterial endovascular treatment by using detachable balloon,coil and Willis covered stent was performed in fifty-one consecutive patients of traumatic direct carotid-cavernous fistulas.with a total of 54 TDCCFs.The detachable balloon was the material of first choice,while Willis covered stents and coils were regarded as the back-up materials.A clinical and angiographic follow-up for 348 months (mean 20.8 months) was conducted to evaluate the arterial patency and the stability of embolization.The clinical data were retrospectively analyzed.Results By using the detachable balloon alone via transarterial route.85%TDCCFs were successfully treated with good preservation of ICA.A total of 98% TDCCFs in this study were successfully treated by using detachable balloon,coil and/or Willis coveted stent,the fistulas became occluded,and ICAs were preserved except one patient.Forty TDCCFs were treated with detachable balloons alone,two TDCCFs with the Willis covered stent alone,and one DCCF with coils alone.Eight TDCCFs were treated with detachable balloons together with Willis covered stent.Of these eight TDCCFs,two were treated with a single session,three were treated with detachable halloons in combination with coils,and one had to receive Willis covered stent.Second and third times of endovascular treatment were needed in 12 TDCCFs.The TDCCF-rel(at)ed symptoms were gradually relived or improved within 1 day to 6 months after treatment,except for five patients who suffered from ipsilateral moderate visual loss or cranial nerve deficit.No perioperative complications.such as vessel rupture,distal embolization or new neurologic deficits,occurred.During the follow-up period lasting for six months,neither delayed neurologic or vascular complications nor recurrence of the lesions developed.Conclusion Via the transarterial route,using detachable balloon to occlude the fistula and at the same time to preserve ICA remains the optimal treatment for TDCCFs.When the standard treatment fails.various coils and the Willis covered stents can be used as an effective alternative or remedial tool in the treatment of TDCCFs,which can preserve ICA.Willis covered stent deployment seems to be an effective,safe,feasible and economical endovasculal treatment for TDCCF,but more clinical studies are needed before we can further clarify its specifications and indications.

SELECTION OF CITATIONS